About the product
The cobas c 111 analyzer is Roche Diagnostics’ analyzer for the in vitro determination of clinical chemistry parameters in serum, plasma, urine and whole blood (HbA1c). According to Roche, the instrument is a system that uses photometric analysis and is optimized for small workloads of up to 50 samples per day. Roche also states that the instrument is not intended for point-of-care testing. For brand information, the Roche Diagnostics page can be consulted.
System features
Sample handling is manual. Roche reports that primary and secondary tubes can be loaded continuously into 8 sample positions and that continuous loading of up to 60 cuvettes is possible. STAT prioritization is supported. Reagents are on exchangeable disks. Roche states that the same reagents, calibrators and controls are used with other cobas platforms and that a maintenance visit is needed once every 1.5 years.
Technical information
- Photometric throughput: up to 85 tests per hour, 60 tests per hour for a typical panel. Time to first result 5 to 10 minutes (manufacturer's claim)
- ISE (optional unit): up to 180 tests per hour, 60 to 100 tests per hour when mixed with photometric tests. Time to first result 2 minutes (manufacturer's claim)
- Reagent disks: up to 8 different disks, up to 27 bottles per disk, bottles up to 20 mL, 50 to 200 tests per test (manufacturer's claim)
- Cuvettes: single-use, inserted and removed manually in segments of 10. Cuvette integrity is checked by the analyzer (manufacturer's claim)
- Incubation: 37 °C ± 0.5 °C, static. Photometer: 20 W halogen lamp, 12 wavelengths between 340 and 659 nm, photodiode array (manufacturer's claim)
- Identification: 2D PDF417 barcode (manufacturer's claim)
- Dimensions: width 590 mm (720 mm with ISE), depth 550 mm, height 480 mm. Weight 32.5 kg (39.5 kg with ISE). Footprint 0.3 m² (manufacturer's claim)
- Water consumption: up to 3 liters per day. The menu includes more than 40 tests (manufacturer's claim)
Use and compatibility
Roche reagent product pages list the Roche CA2 Gen.2 (400 tests, 4 x 100), HDLC4 (200 tests, 2 x 100) and CK (200 tests) packs for the cobas c 111.
For product, quotation and technical information requests, the form on the contact page or info@tiliamedical.com can be used.
Frequently asked questions
According to Roche, the analyzer uses photometric analysis and is optimized for small workloads of up to 50 samples per day.
According to Roche, the optional ISE unit delivers up to 180 tests per hour. When mixed with photometric tests, throughput falls to 60 to 100 tests per hour. Time to first result for ISE is 2 minutes.
No. The Roche product page states that the instrument is not intended for point-of-care testing.